Effluent Treatment Plant Operations
This report outlines the operational procedures and analysis performed at the Effluent Treatment Plant (ETP) regarding wastewater management, specifically focusing on the wastewater analysis conducted in Veisari and the activities within the FMF Snax Chips Line.
Testing
-
Wastewater Analysis
-
Monthly Wastewater Analysis
-
Internal Laboratory Testing
-
External Testing
Process Flow
-
Storing Tank: Collection of effluent for one day and storage.
-
Screening: Removal of grease, oil, and suspended particles from the water. (Sampling Point 1)
-
Equalization Tank: Ensures uniform mixing of effluent.
-
Neutralization Tank: Adjustment of pH using caustic/lime dosing.
-
Flash Mixer: Chemical treatment process for solid removal.
-
Flocculator: Aggregation of fine particles (floc) to assist in sedimentation and filtration.
-
Primary Tube Settler: Sedimentation for the removal of suspended particles.
-
Aeration Tank: Biological removal of organic matter (COD/BOD).
-
Secondary Tube Settler: Further sedimentation for suspended particles.
-
Sludge Reticulation: Removal of organic matter.
-
Filtered Feed Tank: Continuous chlorination process.
-
Moving Bed Biofilm Reactor (MBBR) Aeration Technology: Odor and color removal. (Sampling Point 2)
-
Filtration Tank: Sand filtration for water treatment. (Sampling Point 3)
-
Reverse Osmosis (RO) Feed Tank: Removal of total suspended solids. (Sampling Point